Cloud-electronics CXL-100T Manuel d'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
CXL Manual v1.08
Wiring the rackmount
housings
Inputs:
The transformer inputs should be connected to the low-
impedance output of the relevant amplier channel. Use
the mating 2-pin 5 mm-pitch screw-terminal connectors
supplied with the transformers, and wire with two-core
stranded cable of at least 1.5 mm
2
gauge. (In the case of the
model CXL-400T, 2.5 mm
2
cable is recommended if the
transformers are not adjacent to the amplier.)
Outputs:
The transformer outputs may be connected to the
loudspeaker system. Use the mating 3-pin 5 mm-pitch
screw-terminal connectors supplied with the transformers,
and two-core stranded cable of at least 0.75 mm
2
gauge
(CXL-40T, CXL-100T & CXL-200T) or 1 mm
2
gauge
(CXL-400T). Note that pins 1 and 3 should be wired for a
100 V-line system, and pins 1 and 2 for a 70 V-line system.










When all the connections have been made, t the PVC
external safety cover over the rear panel connectors. The six
xing holes in the cover should align with the six hex pillars.
Secure it in place with six of the supplied M3 x 6 mm Pozi
screws.
Vue de la page 7
1 2 3 4 5 6 7 8 9 10 11 12

Commentaires sur ces manuels

Pas de commentaire